New Cat® CS – ATS (Spec Grade) For Sale in Georgia
Cat® CS – ATS (Spec Grade)
Cat® CS – ATS (Spec Grade)

The CS Series – Contactor-type, Open Transition (CS), Delayed Transition (CSD), Closed Transition (CSCT) ATS is equipped with an intuitive full-color touchscreen HMI and is compatible with Ekip Connect software for commissioning and operation.

The CS Series has an array of standard programmable functions and is built for high performance and service with proactive outage mitigation that monitors temperature and contact health.

Get Pricing
Rating Range 30 - 3000 A
Transfer Type Open Transition (CS), Delayed Transition (CSD), Closed Transition (CSCT)
Switch Type Contactor
Product nodes UL: 30-200 A, 260-1200 A, 1600-3000 A
Rated Voltage and Frequency 200-480VAC, 50/60 Hz
Phase system Single and Three
Number of poles 2, 3 and 4
Neutral configuration Solid neutral, Switched neutral, (Optional) Overlapping neutral
Product type Open transition (I-II), Delayed Transition (I-O-II), Closed transition (I-O-II) 1600-3000A only

        
  • Voltage and frequency sensing of both sources and load
  •     
  • USB port to upload/download settings
  •     
  • Available Bluetooth connection and enhanced communication capabilities
  •     
  • Password protection color touchscreen HMI
  •     
  • Integrated help button and menu
  •     
  • Five programmed packages and IO
  •     
  • Contact wear monitoring including real-time status and predicted contact end-of-life (30-1200A only)
  •     
  • Fast controller response to outage recovery and fast switching (<50ms)

        
  •     
  •     
  • TruOne L4 - color touchscreen HMI compatible with Ekip Connect software, with standard programmable functions and IO, and fast controller response to outage recovery and fast switching (<50ms).

        
  • High current protection and alarm
  •     
  • Wide 200-480V range with auto-configuration of system settings for 30-1200A range
  •     
  • High time-based withstand and closing ratings (WCR)
  •     
  • Short-time withstand ratings in every frame (CS, CSD, and CSCT models)

        
  •     
  •     
  • UL 1008, NFPA 70, 99, 101 and 110
  •     
  •     
  •     
  • NEMA ICS 10
  •     
  •     
  •     
  • cUL
  •     
  •     
  •     
  • Conducted and radiated emissions - CISPR 11:2009, Class A
  •     
  •     
  •     
  • ESD immunity test - IEC/EN 61000-4-2 Class B
  •     
  •     
  •     
  • Radiated RF, electromagnetic field immunity test - IEC/EN 61000-4-3 10 V/m
  •     
  •     
  •     
  • Electrical fast, transient/burst immunity test - IEC/EN 61000-4-4
  •     
  •     
  •     
  • Surge immunity test - IEC/EN 61000-4-5 0.5 to 2 kV
  •     
  •     
  •     
  • Conducted immunity test - IEC/EN 61000-4-6
  •     
  •     
  •     
  • Voltage dips and interruption immunity - IEC/EN 61000-4-11
  •     
  •     
  •     
  • Harmonic voltage immunity test - IEC/EN 6100-4-13